Skip to content
All devices meet international standards (FDA or CE compliance)
English
For professionals  ·  Support
Hair Removal Machines

M22 Dual-Handle IPL Photorejuvenation and Q-Switch Laser Machine

Original price was: $2,999.00.Current price is: $2,099.00. (Shipping Included)

Chat on WhatsApp

Professional salon workstation combining 9 IPL filter bands and 5 laser probes for targeted skin tone and pigment care.

The SK-M22-01 combines intense pulsed light and gem Q-switched non-invasive laser systems on a mobile cart platform. Designed strictly for salon professionals, it delivers targeted multi-spectrum photorejuvenation, hair removal, and chromophore clearance.

100 in stock

You can also choose this in your cart or at checkout.

SKU: SK-M22-01 Category:
Accepted payment methods VISA · MASTERCARD · AMEX · PAYPAL · APPLE PAY · GOOGLE PAY
In stock — ships in 48 h
Free 2-6 weeks shipping On orders over $1000
2-Year Warranty Included Guaranteed quality with reliable lifetime technical support.
Verified Global Compliance All products conform to strict international FDA or CE standards.

Description

The SK-M22-01 is a dual-modality clinical aesthetic workstation engineered exclusively for beauty salons and licensed estheticians. It integrates non-ablative intense pulsed light (IPL/DPL) photorejuvenation with a gem Q-switched laser operating at 10–20ns pulse widths. Through selective photothermolysis and photoblasting principles, the system addresses epidermal chromophores, superficial vascular redness, enlarged pores, and dermal collagen stimulation across two dedicated handpieces.

Specifications

  • Equipment Type: Non-ablative fractional photorejuvenation, intense pulsed light (IPL/DPL), and Q-switched laser
  • Power Requirements: Single-phase 220V, maximum operating current ≤ 10A
  • Recommended Voltage Stabilizer: 3000W
  • Laser Pulse Width: Approximately 10–20 ns
  • IPL Wavelength Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm
  • Specialized Vascular & Acne Bands: CA (superficial red blood), VA (sensitive vascular redness), AC (acne and inflammation)
  • Laser Probes: 1064nm, 532nm, non-invasive 1064nm, non-invasive 532nm, Black Face Doll (carbon peeling)
  • Cooling System: Integrated refrigeration controls
  • Chassis Architecture: Touchscreen interface, emergency stop switch, dedicated mobile cart, base pulleys, water filling, overflow, and drain ports
  • Initial Access Password: 123456
  • Warranty Coverage: 1-year warranty for the main host (consumables and wear parts excluded); 7-day replacement for non-accidental quality defects

Applications & Limitations

This system is built for comprehensive salon aesthetic services, including the improvement of sun spots, freckles, chloasma, and age spots via targeted photoblasting. The IPL filters enable superficial erythema reduction (CA, VA, 560nm), fine line smoothing (590nm), epidermal tone balancing (515nm, 615nm, 695nm), and pore refinement with hair removal functions (640nm).

Limitations and Unsuited Uses: This machine is strictly restricted to professional salon settings and is not intended for home use. Treatments must not be administered to individuals unable to maintain rigorous post-care restrictions. Post-treatment protocols strictly prohibit sun exposure, the use of aspirin, and topical formulations containing alcohol. Physical rubbing, squeezing, or massaging of treated zones is prohibited. Additionally, the unit must not be moved over long distances without its original shock-absorbing packaging, nor operated without grounding on an unverified power grid lacking a 3000W stabilizer.

Frequently Asked Questions

What wavelength filters are supplied for the IPL handpiece?

The IPL system includes standard cutoff filters at 515nm, 560nm, 590nm, 615nm, 640nm, and 695nm, along with three dedicated spectrum bands: CA for superficial red blood, VA for sensitive vascular filaments, and AC for acne and inflammatory breakouts.

What are the specific roles of the five laser probes?

The laser handpiece includes standard 1064nm and 532nm probes, non-invasive 1064nm and non-invasive 532nm probes, and a Black Face Doll carbon suspension probe, enabling targeted pigment disruption through 10–20ns pulse photoblasting and carbon assisted skin renewal.

What electrical setup is necessary to install this machine safely?

The unit requires a grounded single-phase 220V power connection drawing no more than 10A. To protect sensitive internal optics from line fluctuations, operation with a dedicated 3000W external voltage stabilizer is recommended.

What recovery instructions must clients observe following care?

Clients must wear protective sunscreen, avoid sunlight, and refrain entirely from aspirin or alcohol-based skincare. Because post-procedure cellular metabolism increases trans-epidermal water loss, operators must instruct clients to hydrate frequently and apply hydrating sheet masks.

What steps should be taken if a handpiece fails to emit output?

Operators should verify if the selected probe shot count has expired, inspect the treatment head for damage, and check that the interface cable on the chassis is completely inserted and secured.

Reviews

There are no reviews yet

Be the first to review “M22 Dual-Handle IPL Photorejuvenation and Q-Switch Laser Machine”

Your email address will not be published. Required fields are marked *