Skip to content
All devices meet international standards (FDA or CE compliance)
English
For professionals  ·  Support
Face/Body Slimming Machines

Body Shaping Machine for Sale SK-B71 2.45 GHz Cryo-Microwave System

Original price was: $4,000.00.Current price is: $3,239.00.

Chat on WhatsApp

Desktop Cryowave shaping device for aesthetic clinics targeting local fat, skin laxity, and cellulite.

The SK-B71 integrates 2.45 GHz microwave energy with a 5°C–20°C contact cooling system to target subcutaneous fat at 3mm, 7mm, and 15mm depths while protecting the skin surface. Designed for facial and body contouring, it supports fat reduction, collagen-stimulating skin tightening, and cellulite improvement in 10–30 minute sessions.

You can also choose this in your cart or at checkout.

SKU: SK-B71 Category:
Accepted payment methods VISA · MASTERCARD · AMEX · PAYPAL · APPLE PAY · GOOGLE PAY
In stock — ships in 48 h
Shipping Included (2–6 Weeks) Shipping is included for eligible countries only. For other destinations, please contact us for a shipping quote before placing your order.
2-Year Warranty Included Guaranteed quality with reliable lifetime technical support.
Verified Global Compliance All products conform to strict international FDA or CE standards.

Description

The SK-B71 is a non-invasive body shaping machine for sale engineered for aesthetic studios and clinics seeking targeted fat reduction, skin tightening, and cellulite improvement without surgery. Combining 2.45 GHz microwave technology with dynamic contact cooling, this microwave body contouring machine delivers energy directly into the 3–15mm subcutaneous fat layer while keeping the epidermis protected and comfortable. Because fat molecules absorb microwave energy more efficiently than the epidermis and dermis, targeted fat cells vibrate rapidly, undergo structural membrane disruption, and enter natural apoptosis before being cleared by the body’s immune system over 1 to 3 months. Simultaneously, controlled thermal stimulation encourages subcutaneous collagen regeneration for firmer skin texture.

Technical Specifications

  • Product Model: SK-B71 (Cold Wave Shaping Instrument / Cryo-Microwave Shaping Instrument)
  • Microwave Frequency: 2.45 GHz
  • Action Depth: 3mm / 7mm / 15mm
  • Handpiece Types: Specialized probes for face and body (Small 3mm, Medium 7mm, Large 15mm)
  • Cooling Temperature Range: 5°C to 20°C (contact cooling maintains skin surface near 5°C)
  • Working Voltage: AC 110V / 220V, 50/60Hz
  • Initial Diagnostic Power Reference: 20–40W
  • Recommended Session Duration: 10–20 minutes per area (up to 15–30 minutes depending on target fat level)
  • Recommended Treatment Interval: 2 to 4 weeks between sessions
  • Operating Environment: Dry, ventilated room at 5°C–40°C, away from strong electromagnetic interference
  • Magnetron Service Life: Replace core component after 2,000 cumulative operating hours
  • Warranty Period: 2- year for main unit; 6 months for accessories (from ex-factory date)

Application Scenarios for This Body Shaping Machine for Sale

Equipped with three depth-specific handpieces, this non-invasive fat reduction machine adapts to both delicate facial contours and larger body zones. During a pre-treatment consultation, clinics offering comprehensive skin evaluations alongside a skin analysis machine for sale can map laxity and contour priorities before selecting the appropriate SK-B71 probe:

  • Small Probe (3mm Depth): Designed for facial tightening and contouring, including double chin reduction, jawline definition, sagging mid-face cheeks, nasolabial folds, and delicate neck lines.
  • Medium Probe (7mm Depth): Suited for upper arms (butterfly sleeves), underarm accessory breast tissue, and chest areas, typically treated for 15–20 minutes for mild fat reduction.
  • Large Probe (15mm Depth): Built for deeper subcutaneous deposits on the abdomen, waist sides, thighs, and buttocks, with sessions lasting 20–25 minutes for moderate reduction or 25–30 minutes for heavy reduction.

Unsuitable Situations and Contraindications: The SK-B71 is intended only for healthy individuals who meet sufficient subcutaneous fat thickness criteria and is not suitable for every client. Absolute contraindications include pregnancy or breastfeeding, pacemakers or metal implants (such as stents or prostheses), severe heart disease (arrhythmia or heart failure), coagulation disorders or anticoagulant use, fever, active skin infections or inflammation (acute acne, eczema, or unhealed wounds), severe lipid metabolism disorders (severe fatty liver or hyperlipidemia crisis), malignant tumors, and allergies to coupling gel. Relative contraindications include uncontrolled diabetes (blood glucose above 8 mmol/L), sensitive or scar-prone skin, cold sensitivity or very low heat tolerance, and anyone who underwent similar fat reduction procedures or local surgery within the preceding 3 months.

Frequently Asked Questions

How does Cryowave shaping target fat cells without damaging the skin?

Cryowave shaping pairs 2.45 GHz microwave energy with an integrated 5°C–20°C cooling system and thermal insulation buffer. Fat cells absorb microwave energy far more readily than upper skin layers, leading to selective cellular vibration and natural apoptosis in the 3–15mm depth zone while continuous real-time temperature monitoring keeps the skin surface protected around 5°C.

Is treatment with this cryo microwave shaping device painful or does it require downtime?

Sessions with the SK-B71 cryo microwave shaping device are non-invasive and generally produce only a mild sensation of localized warmth and tightening. Clients can return to normal activities, work, and makeup immediately afterward; temporary mild redness, warmth, swelling, or numbness typically resolves within hours to 1–2 weeks.

How long does a session take and when are contouring results visible?

A single session lasts roughly 10 to 20 minutes per site, or 15–30 minutes based on area size and target intensity, with follow-up visits spaced 2–4 weeks apart. Clients often feel immediate skin tightening on the day of treatment, fat metabolism starts within 1–2 weeks, optimal contouring results appear at 1–3 months, and tightening effects can last 6–12 months.

What post-treatment care and daily maintenance does the SK-B71 require?

For 24 hours post-session, clients should avoid friction, pressure, hot compresses, saunas, hot springs, and alcohol- or acid-based skincare, and wait 4–6 hours before bathing or vigorous exercise. Over the next 1–3 months, drinking 1.5–2L of water daily, following a low-fat high-protein diet, adding light exercise after one week, and applying sun protection support clearance. Operators should clean handpieces with medical alcohol after every use, UV-sterilize them for 30 minutes weekly, let the unit cool for 10 minutes before unplugging, calibrate power and cooling every 3 months, and schedule an annual inspection.

What warranty coverage and operating precautions apply to the SK-B71?

The SK-B71 includes a 1-year warranty on the main unit and a 6-month warranty on accessories starting from the ex-factory date, covering free repair for non-human damage. Unauthorized disassembly, modification, accidental drops, non-original accessories, and force majeure events are excluded. Operators must apply matching coupling gel before starting, begin at 20–40W on initial sessions, and keep the handpiece moving continuously in full contact with the skin to prevent localized overheating.

Reviews

There are no reviews yet

Be the first to review “Body Shaping Machine for Sale SK-B71 2.45 GHz Cryo-Microwave System”

Your email address will not be published. Required fields are marked *